Liquid-Cooled EV Charging Main Unit
The Liquid-Cooled EV Charging Main Unit is designed for high-power electric vehicle charging systems, commercial charging stations and fleet charging infrastructure.
The product series covers output power configurations from 240 kW to 720 kW. With a liquid-cooling system, modular power conversion architecture and support for up to 12 charging guns, the main unit can be integrated with multiple charging terminals for flexible power distribution.
The system supports an output voltage range of 200–1000 VDC, with a maximum system efficiency of 95.5%. It is suitable for charging sites that require high power density, stable operation and centralized charging control.
Main Features
Output power configurations from 240 kW to 720 kW
Liquid-cooled power conversion system
Output voltage range of 200–1000 VDC
Supports up to 12 charging guns
Maximum system efficiency of 95.5%
Current regulation accuracy of ≤ ±1%
Voltage regulation accuracy of ≤ ±0.5%
Floor-mounted installation
IP55 protection rating
Three-phase five-wire AC input system
Input power factor of ≥0.99 at loads of 50% or above
Input harmonics of ≤5% at loads of 50% or above
4G and FE communication interfaces
GOOSE and MODBUS-TCP communication protocols
Multiple electrical, thermal and environmental safety protections
Main Unit Series | 720Series | 600Series | 480Series | 360Series | |
Product Model | DS720-720LCNA1 | DS720-720LCNA1 | DS720-720LCNA1 | DS480-480LCNA1 | DS480-480LCNA1 |
Module Configuration | ACDC*6+DCDC*12 | ACDC*5+DCDC*12 | ACDC*4+DCDC*10 | ACDC*4+DCDC*8 | ACDC*2+DCDC*6 |
Output Power | 720kW | 600kW | 480kW | 480kW | 240kW |
Dimensions | Width 800 mm × Depth 1700 mm × Height 2150 mm | ||||
Installation Method | Floor-mounted installation (supports transport with plates and liquid). | ||||
System Efficiency | Maximum efficiency 95.5% | ||||
Heat Dissipation Method | Liquid cooling | ||||
Protection Rating | IP55 | ||||
Communication Interface | 4G、FE(北向) | ||||
Input Voltage | 380Vac±15% ,Three-phase five-wire system | ||||
Input Frequency | 45Hz~66Hz | ||||
Power Factor | ≥0.99(load≥50%) | ||||
Harmonics | ≤5%(load≥50%) | ||||
Input Power Distribution | 800A × 3P AC circuit breaker | 630A × 3P AC circuit breaker | |||
Output Voltage | 200-1000Vdc | ||||
Maximum Number of Guns | 12 | 12 | 8 | 8 | 6 |
Current Regulation Accuracy | ≤ ±1% | ||||
Voltage Regulation Accuracy | ≤ ±0.5% | ||||
Operating Stability | - 35℃~+50℃ | ||||
Storage Temperature | - 35℃~+70℃ | ||||
Altitude | ≤4000m | ||||
Relative Temperature | 5%RH~95%RH | ||||
Noise Level (Silent Mode) | ≤ 55 dB@25℃ | ||||
Noise Level (Standard Mode) | ≤ 65 dB@25℃ | ≤ 60 dB@25℃ | |||
Safety Functions | Input overvoltage protection, undervoltage protection, output overvoltage protection, constant power overload protection, short circuit protection, grounding protection, over-temperature protection, lightning protection, emergency stop protection, leakage protection, insulation detection, door opening protection, battery reverse connection protection, relay sticking protection, water immersion protection, smoke alarm, etc. | ||||
Product Specifications | GB/T18487.1 ,GB/T 27930 ,GB/T 18487.2, | ||||
NB/T33001 ,NB/T33008.1 | |||||
Host Terminal Communication Interface | FE ,Ring network recommended, shielded twisted-pair cable, FTP Cat5E. | ||||
Host Terminal Communication Protocol | GOOSE+MODBUS-TCP | ||||
Auxiliary Power Supply Standard | Main unit 220Vac auxiliary power output | ||||
Host Expansion Capabilities | ○ | ● | ● | ○ | ● |