Charging Terminal
Product Series |
Liquid Cooling Terminals |
Natural Cooling Terminals | |||||
Product Model | DT600L1-CNA1 | DT600L1-CNA1 | DT250N1-CNA1 | DT250N2-CNA1 | DT250N2-CNA2 | ||
(White and red) | (pure red) | ||||||
Dimensions (W*D*H) |
340mm*295mm*1700mm |
390mm*295mm*1700mm | |||||
Number of Heads | 1 | 1 | 1 | 2 | 2 | ||
Wire Length | 3.5m | 3.5m | 5m | 7.4m | |||
Installation Method | Floor installation | ||||||
Protection Rating | IP55 | ||||||
Heat Dissipation Method | Liquid cooling | Natural cooling | |||||
Operating Temperature | -35~ +50℃ | ||||||
Noise Level | ≤55dB@25℃ | ≤50dB@25℃ | |||||
Storage Temperature | -35℃~+70℃ | ||||||
Relative Humidity | 5%RH~95%RH | ||||||
Altitude | ≤4000m | ||||||
Output Voltage | 200~1000Vdc | ||||||
Charging Current | Max600A | 250A | |||||
Product Specifications |
GB/T27930-2015、JJG1149-2022 | GB/T18487.1-2015、NB/T33001-2018、NB/T33008.1- 2018、GB/T27930-2015、JJG1149-2022 | |||||
Safety Features |
Output overvoltage protection, short circuit protection, protective grounding continuity detection, over-temperature protection, emergency stop protection, leakage protection, insulation detection, door opening protection, power outage protection, battery reverse connection protection, contactor adhesion protection, and low liquid level alarm. | ||||||